Midwest® RS45508C

Midwest® RS45508C Ringless Service Entrance Meter, 120/240 V, 400 A, 8-Spaces, CB2201H Breaker, 8-Circuits, NEMA 3R

  • Manufacturers: Midwest Electric Products
  • Brand Name: Midwest®
  • CPEPN: RS45508C
  • MPN: RS45508C
  • UPC: 784567208658
  • Min. Order Qty: 1
  • Qty. Interval: 1
  • Availability: loading
  • Total Availability: loading

Midwest® Service Entrance Meter, Ringless, 120/240 V, 400 A, 1, 8-Circuits, CB2201H Breaker, Series Wiring Configuration, 8-Spaces, 1 AWG - 300 kcmil Solid (Aluminum/Copper) Load Side Wire, Underground Feed, Surface Mount, NEMA 3R, 31 x 33 Inch Cabinet, G90 Galvanized 16 ga Steel Housing, 1.46 Inch L x 1.18 Inch W x 2.22 Inch H, Includes: Breaker

Type      :      Ringless
Voltage Rating      :      120/240 V
Amperage Rating      :      400 A
Number of Phases      :      1
Number of Circuits      :      8
Breaker Type      :      CB2201H
Wiring Configuration      :      Series
Number of Spaces      :      8
Wire Size      :      1 AWG - 300 kcmil Solid (Aluminum/Copper) Load Side
Feed Type      :      Underground
Mounting Type      :      Surface
Enclosure Type      :      NEMA 3R
Cabinet Size      :      31 x 33 Inch
Housing Material      :      G90 Galvanized 16 ga Steel
Dimensions      :      1.46 Inch L x 1.18 Inch W x 2.22 Inch H
Includes      :      Breaker

Heavy galvanized G90 16 ga steel, with highest quality electro-deposition finish, resists corrosion and fading 200 or 125 A continuous duty meter socket with meter guides and reinforced jaws for ring and ringless type sockets.

  • Utility meter socket compartment barriered from breaker mains for utility power protection rated NEMA 3r - weather-proof equipment
  • All terminals accept copper or aluminum wire for added installation flexibility doors have padlock provision to prevent unauthorized entry supplied with 12-2 Cu/Al equipment ground lug all GFCI duplexes are listed as weather-resistant and tamper resistant as required by 2008 NEC in article 406.8 and 406.11
  • Removable post door allows lay in wiring 200 A factory wired loop feed lugs rolled edge post bottoms to protect service cable locking hasp for utility seal on post covers
  • One heads underground feed (2) CB2201H installed breaker 8 additional breaker spaces per head series wiring configuration provide circuit protection No hub provision LC88PC loadcenter No loop feed post options: stud termination pad mount post

Standard/Approvals: UL Listed

Application: Residential

  • pdfCatalog https://www.cpesupply.com//ASSETS/DOCUMENTS/ITEMS/EN/Midwest_RS45508C_Catalog.pdf
  • pdfData Sheet https://www.cpesupply.com//ASSETS/DOCUMENTS/ITEMS/EN/Midwest_RS45508C_Data_Sheet.pdf